Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: http://ds.knu.edu.ua/jspui/handle/123456789/1756
Повний запис метаданих
Поле DCЗначенняМова
dc.contributor.authorMorkun, Volodymyr-
dc.contributor.authorМоркун, Володимир Станіславович-
dc.contributor.authorМоркун, Владимир Станиславович-
dc.contributor.authorSavytskyi, Oleksandruk_UA
dc.contributor.authorСавицький, Олександр Івановичuk_UA
dc.contributor.authorСавицький, Александр Ивановичuk_UA
dc.contributor.authorRuban, Serhiiuk_UA
dc.contributor.authorРубан, Сергій Анатолійовичuk_UA
dc.contributor.authorРубан, Сергей Анатольевичuk_UA
dc.date.accessioned2020-02-05T14:01:57Z-
dc.date.available2020-02-05T14:01:57Z-
dc.date.issued2015-
dc.identifier.citationMorkun, V. Automated Distributed System for Utilization of Low-temperature Energy of Mine Water and Ventilation Air on the Basis of the Technology of Heat Pumps [Electronic resource] / V. Morkun, O. Savytskyi, S. Ruban // Computer Science, Information Technology, Automation (CSITA). – 2015. – Vol. 1, issue 1. – P. 25–31. – DOI: 10.31721/2414-9055.2015.1.1.25. – References: p. 30–31.uk_UA
dc.identifier.issn2414-9055-
dc.identifier.urihttps://doi.org/10.31721/2414-9055.2015.1.1.25-
dc.identifier.urihttp://ds.knu.edu.ua/jspui/handle/123456789/1756-
dc.description.abstractThe energy crisis and the need to reduce greenhouse gas emissions require research in the practical development of energy systems based on alternative energy sources. The article discusses the possibility of using heat pumps for heat utilization of mine water and ventilation air. Application of the large number of pumps requires automatic control of the operation parameters in order to optimize the whole system.Control issues of an individual heat pump were well reviewed by researchers in many sources. At the same time there are much less works devoted to analysis of the operation issues and control regimes of groups of heat pumps. And very small number of works is devoted to the questions of supervisory control of groups of heat pumps, which consist of heat pumps “water – water” and “air – water”.The aim of the study is to validate the feasibility of using heat pumps for heat utilization of mine waters and ventilation air, and development of algorithms for supervisory control of distributed system for utilization of heat from these sources, as well as formation of optimum modes of teamwork of heat pumps, both on the surface and in the deep horizons of the mine. In the article the classical methods of analysis parameters of the particular system at one of the mines of Kryvyi Rih Basin and methods of the modern theory of automatic supervisory control of distributed systems were used. The processes visualization techniques considering a human perception and decision-making had also been applied when creating the human-machine interface of automated distributed system for utilization of low-temperature energy of mine water and ventilation air.uk_UA
dc.language.isoenuk_UA
dc.publisherВидавництво “CSITA”uk_UA
dc.subjectnon-conventional sources of energyuk_UA
dc.subjectmine wateruk_UA
dc.subjectventilation airuk_UA
dc.subjectheat pumpuk_UA
dc.subjectmicroclimate in the mineuk_UA
dc.subjectautomated distributed systemuk_UA
dc.subjectSCADAuk_UA
dc.titleAutomated Distributed System for Utilization of Low-temperature Energy of Mine Water and Ventilation Air on the Basis of the Technology of Heat Pumpsuk_UA
dc.typeArticleuk_UA
local.submitter.emaildspace_knu@knu.ed...uk_UA
Розташовується у зібраннях:Кафедра автоматизації, комп'ютерних наук і технологій
Наукові статті

Файли цього матеріалу:
Файл Опис РозмірФормат 
Morkun V. Automated Distributed System for Utilization of Low-temperature Energy.pdf355.5 kBAdobe PDFПереглянути/Відкрити


Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.